There are no translations available.
Product Description
The Weighing Indicator LD 5250 is a member of the LD5200 series of digital indicators and controllers, designed for demanding weighing applications with the need of digital and analogue interfacing to higher level process control equipment. Industrially oriented hardware and proven software allow simple operation at high accuracy and reliability, in a small panel mount enclosure and at an attractive price. Up to 30 units can be connected via industrial Network to a PC for multi-weigher applications.
Basic Features
- Approved for 10,000d
- Up to 70 measurements per second
- Alibi-memory for 10,000 records
- Parallel connection of up to 10 strain gauge load cells
- Display resolution up to 99,000div.
- Bright, 6-digit, red LED display (14mm)
- Serial RS232 port for connection to serial printer, PC or remote display
- 1 digital input (programmable as tilt input or to tare scale remotely or for other purposes)
- 2 digital outputs (programmable as weight set points or as other control outputs)
- Compact, plastic panel mount enclosure (IP40 protection)
Application
- Simple weight display
- Mixing plants
- Weighing automation systems
Operating Fuctions
- Weight display
- Zero, Tare, Tare recall, Print, Total
- Status annunciators for set points
- Operation and setting via keyboard or serial commands
- Printouts with weight, totals and error reports
Options
- Additional RS485 or RS232 serial port with network capability
- Analogue output (current or voltage)
Specifications
DISPLAY - KEYBOARD
DISPLAY: 6 digit, 7 segment, LED, red, 14mm digit height STATUS ANNUNCIATORS: No motion, zero, tare in use, net, set points in operation KEYBOARD: 6 key membrane keyboard with tactile feedback DECIMAL POINT SETTING: Between any digit of the weight display DISPLAY STEP: 1, 2, 5, 10, 20, 50, 100, 200 (set-up selectable) DISPLAY DIGITS: 4, 5, 6 (set-up selectable)
SCALE CALIBRATION & FUCTIONS
CALIBRATION: Digital calibration (dead load and span) and scale parametrization via keyboard dialogue menu . The weight display can be set to any capacity and resolution with 6 digits (subject to application and regulations). Electronic calibration can be also performed via the m V/V output values of load cells. WEIGHING FUNCTIONS: Automatic zero tracking, no-motion detection, auto-zero on power-up, zero, tare (max tare eect = -Max), multiple test functions The two most signicant decades of the digital display are programmable from 1 up to 99 for the full scale range. Single or dual interval / range, auto-switching between the dierent display steps. FULL SCALE RANGE: Serial EEPROM for the storage of calibration data (32KB) MEMORIES: Flash, tally-roll (Alibi) memory capable of 10,000 weight registrations (64KB)
A/D CONVERTER
TYPE: Sigma-Delta ratiometric with analogue and digital ltering (FIR & post ltering, rolling average) CONVERSION RATE: 3 up to 70 measurements per second (set-up selectable) SENSITIVITY: 0.4μV/VSI for approved scales, 0.1μV/VSI for non-approved scales ANALOGUE SIGNAL RANGE: -0.25 to 2mV/V (-1.25mV to – 10mV) or -0.25 to 4mV/V (-1.25mV to – 20mV) RESOLUTION: Internal 550,000 counts, Display : 990,000 (selectable, in accordance with regulations)
CONTROL I/O
DIGITAL INPUT (x1): 9-24 VDC, positive common, opto-isolated to 2.5 KV, set up programmable DIGITAL OUTPUTS (x2): 24 VDC ±10%, transistor (SOURCE) darlington, positive common, max current 100 m A, opto-isolated to 2.5KV, set up programmable
POWER SUPPLY
INPUT VOLTAGE: 24VDC OPTION: Alternatively : 9-15VDC via mains power adapter (factory installed option)
ENVIRONMENTAL CONDITIONS / CONSTRUCTION
EMC: According to OIML R76 and EN 45501 requirements OPERATING TEMPERATURE: -10oC to +40oC STORAGE TEMPERATURE: -10oC to +70oC HUMIDITY: 40% to 90% RH (non condensing) HOUSING (INOX VERSION): Plastic, IP40 protection (IP54 for front panel) Dimensions (in mm): 144(L)x72(H)x132(D), panel cut-out : 136.5(L)x66.5(H)
OPTIONAL FEATURES
SERIAL COM. PORT 2: RS485, set-up programmable, 2400-57600 baud , half duplex, (continuous output, remote printer output, EDP and master-slave protocols) SERIAL COM. PORT 2: RS232, set-up programmable, 2400-57600 baud , half duplex, (continuous output, remote printer output, EDP and master-slave protocols) ANALOGUE OUTPUT: Analogue output, current (0/4 –20m A) or voltage (0.02 -10V) (hardware selectable), resol. 16 bit
LINEARITY & STABILITY
LINEARITY: Within 0.002 % of full scale LONG TERM STABILITY: 0.005 % of full scale per year TEMPERATURE COEF.: Deadload 2ppm / C, Span 2ppm / C
INTERFACES
SERIAL COM. PORT 1: RS232, non-programmable, 2400 baud , full duplex (continuous output, printer output, print on demand and Alibi modes
LOAD CELL CONNECTION
NUMBER OF LOAD CELLS: Up to 10 strain gauge load cells, 350 Ω each (or more, provided min input impedance =35Ω) EXCITATION: +5V alternating polarity or +5VDC (set-up selectable), with sense CONNECTION TECHNIQUE: 6-wire technique
APPROVALS
ACCURACY CLASS III: EU-Type approval for 10,000 divisions (approval Nr.: DK 0199.27) & OIML R76
|