Product Description
The Weighing Indicator LD 5290 is the high-end member of the LD5200-series, a robust, universal instrument designed for the handling and control of bulk materials in various automatic discontinuous weighers. It oers the performance of a modern microprocessor, the advantages of a PLC and the weighing accuracy of an advanced A/D converter, combined with powerful data management features. Industrially oriented hardware and proven control software allow extremely fast and reliable operation at the highest accuracy and reliability, ensuring easy adaptation to application requirements and optimization of the weighing process.
Basic Features
- Approved for 10,000 divisions
- Up to 228 measurements per second
- Excitation for up to 10 strain gauge load cells, 350Ω (or more)
- Extremely stable and high resolution A/D converter with integrated analog and digital ltering
- 9-digit, LED display with status annunciators and operator dialogue display VFD (2x40 characters).
- Dynamic simulation of the weighing process on a front panel scale silhouette
- Alphanumeric keyboard of 33 keys for data entry and exible operator dialogue
- Up to 64 opto-isolated digital I/O
- 4 serial ports and 1 centronics printer output ports
- Analog output ( 2 channels) (optional)
- Modern compact panel mount enclosure (IP54)
Application
- Net and gross bagging scales
- Drum lling systems
- Bulk hopper scales
- Belt scales
Operating Fuctions
- Operation modes: manual, automatic, remote
- Scale parameter setting and calibration via interactive dialogue menu
- Password protection against unauthorized use and accidental data changes
- Intelligent software functions for the optimal weighing process: programming of dosing times, fine and coarse, tolerance control, in ight compensation etc.
- Continuous control of external conditions, monitoring of data integrity and process variables and comprehensive error detection
- Professional documentation via printouts with data les, totals, batch and process events and statistical reports.
- Special functions for error trouble shooting and service purposes
Specifications
DISPLAY - KEYBOARD
DISPLAYS: Weight display: 9-digit, LED, red, 10 mm. Operator dialogue display: VFD, 2x40 characters, 5mm. Both with brightness control. STATUS ANNUNCIATORS: Net mode, rate, total, zero, tare, no motion, scale in use KEYBOARD: Alphanumeric membrane keyboard of 33 keys with acoustic feedback DECIMAL POINT SETTING: Between any digits of the weight display WEIGHT DIGITS: 4, 5, 6
SCALE CALIBRATION & FUCTIONS
CALIBRATION: Digital calibration, menu driven (from keyboard or higher level control equipment). Two calibration points (Dead load and Span). The weight display can be set to any capacity and resolution with 6 digits (subject to application and regulations). Electronic calibration can also be performed via the m V/V output values of load cells. WEIGHING FUNCTIONS: Automatic-zero tracking, no motion detection, range (kg/h) monitoring, zero, tare, preset tare, net mode, multiple test functions MEMORIES: Serial EEPROM for the storage of calibration data (64KB), real-time-clock
A/D CONVERTER
TYPE: Sigma-Delta ratiometric with integrated analogue and digital ltering. Optional connection to remote A/D converter (DJB) CONVERSION RATE: 7 up to 228 measurements per second (set-up selectable) SENSITIVITY: 0.4 μ V/digit for approved scales, 0.1 μ V/digit for approved scales ANALOGUE SIGNAL RANGE: -0.25 to 2m V/V with GAIN=10 or -0.25 to 4m V/V with GAIN=20 RESOLUTION: Internal : 500.000 counts, Display: selectable up to 99,000dd (in accordance with regulations)
CONTROL I/O
DIGITAL INPUT (x1): 24V DC 20%, positive common, opto-isolated to 2.5 KV DIGITAL OUTPUTS (x2): 24V DC 10%, transistor (SOURCE) Darlington, max. current 200m A
POWER SUPPLY
180-260 V AC, 50Hz 5%, 5% max distortion. Max. consumption 20 VA
ENVIRONMENTAL CONDITIONS / CONSTRUCTION
EMC: According to OIML R76 and EN 45501 requirements OPERATING TEMPERATURE: -10oC to +40oC -10oC to +70oC HUMIDITY: 40%-90% RH , non condensing ENCLOSURE: Alum, Panel mount, IP54 for front panel. Dimensions (in mm):305 (L)x132(H)x137(T), panel cut-out: 293x118 Stainless steel, IP65 – ONLY FOR THE BELT SCALE SOFTWARE VERSION
OPTIONAL FEATURES
DIGITAL I/O BOARD (16/16): 24V DC 20%, positive common, opto-isolated to 2.5 KV DIGITAL I/O BOARD (8/8): 24V DC 20%, positive common, opto-isolated to 2.5 KV and 2 analogue outputs opto-isolated ANALOGUE OUTPUT: Two independent opto-isolated channels with individual parameters. Current or voltage output (hardware selectable). Standard or user calibration of zero and span. Resolution 12 bit – F.S Voltage: 0.05-10V into 1KΩ load. Current: 0-20 m A or 4-20 m A (max. resistance 500Ω)
LINEARITY & STABILITY
LINEARITY: Within 0.002 % of full scale LONG TERM STABILITY: 0.005 % of full scale per year
TEMPERATURE COEF.: Deadload 2ppm / C, Span 2ppm / C
LOAD CELL CONNECTION
NUMBER OF LOAD CELLS: Up to 10 strain gauge load cells, 350 Ω each (or more, provided min input impedance =35Ω) EXCITATION: +5V alternating polarity or +5VDC (set-up selectable), with sense CONNECTION TECHNIQUE: 6-wire technique
INTERFACES
SERIAL COM. PORT #1 : RS232C, 600-19200 baud, full duplex, RTS/CTS control SERIAL COM. PORT #2 : RS485, 600-19200 baud, half duplex, Tx enable control SERIAL COM. PORT #3 : RS232C, 600-19200 baud, full duplex, RTS/CTS control SERIAL COM. PORT #4 : RS485A, 600-19200 baud, full duplex PARALLEL PORT: Printer output, centronics type with busy and paper out control
APPROVALS
ACCURACY CLASS III: EU-Type approval for 10,000 divisions (approval Nr.: DK 0199.27) & OIML R76
|